FF365 Fire Rated Sealant

UL Classified Intumescent Firestop Sealant - Up to 2-Hour Fire Protection

intumescent firestop sealant for use in a variety of UL through-penetration firestopping systems.

The Tenmat FF365 is a gun-grade, one-component intumescent fire rated sealant designed for through-penetration firestopping in fire-resistance-rated walls, floors, and ceilings. Classified by Underwriters Laboratories (UL) and tested to UL 1479 / ASTM E814, it delivers up to 2 hours of verified fire protection.

The FF365 works by expanding under heat. When a fire occurs, the intumescent compound swells to close the opening around cables, conduits, pipes, or blank penetrations, blocking both flame and smoke for up to 120 minutes.

It fits a standard 10 oz. caulking gun and requires no special tools. Water-based formula means easy cleanup, and it’s paintable once cured. Sag-resistant for overhead and vertical applications.

A tube of TENMAT F135 fire protection sealant, suitable for use in UL firestop systems, with a detached nozzle beside it on a white background.

Why Specifiers and Contractors Choose the FF365 Fire Sealant

A caulking gun seals cables in a wall opening with brown sealant as part of UL firestop systems.
Cross-section of an electrical cable with multiple wires passing through a hole in a concrete wall, protected by UL firestop systems.

In a fire, the intumescent material expands, closing the opening and preventing flame spread

FF365 Product Specifications

PropertyValue
Product typeAcrylic with halogen-free fire retardant additives, intumescent
ColourRed
ChemistryWater-based intumescent (acrylic/latex binder)
Bulk density1,300 – 1,450 kg/m³
Transport / storage5 °C – 30 °C (41 °F – 86 °F) — dry, in original containersKeep from freezing
Application methodGun-grade, standard 10 oz caulking gun
Application temperature10 °C – 30 °C (50 °F – 86 °F)Recommended: 20 °C – 25 °C (68 °F – 77 °F)
Content310 ml (10.48 fl oz)
VOC content20.2 – 23.3 g/L
Fire rating (max)2 hours / 120 min
Test standardsUL 1479 / ASTM E814
UL classifications
  • C-AJ-0178
  • C-AJ-0179
  • C-AJ-1745
  • C-AJ-3377
  • C-AJ-3378
  • C-AJ-4117
  • C-AJ-8320
Intumescent actionHigh-expansion — expands under heat to seal the annular space around penetrating items
PaintableYes, once cured
CleanupWater
FlexibilityRemains flexible after curing
SubstratesConcrete, masonry, drywall / gypsum board, steel
Penetration typesBlank openings, metal pipes, conduits, cables, wires, mixed penetrations
Assembly typesFloors, walls and ceilings
MaintenanceMaintenance-free when installed in a listed system
Environmental conditionsDry rooms, indoors, above 0 °C (32 °F)Outdoor use permitted with additional silicone coating
Full technical dataSee FF365 Information Sheet and SDS (Downloads section)

Where to Use the FF365 Fire Sealant

The FF365 fire sealant is suited to a wide range of through-penetration applications in fire-resistance-rated assemblies. Below are the most common installation scenarios.

1. Cable and Wire Bundles Through Fire-Rated Walls

When multiple low-voltage, data, or electrical cables pass through a single opening in a fire-rated wall, the FF365 is applied around and into the bundle to close the annular space. The flexible, water-based formula works into irregular cable bundles where rigid products cannot. The flexible cure means additional cables can be added later without full re-application.

2. Metal Conduit Penetrations

Steel conduit is non-combustible but the annular gap around it still requires sealing in a rated assembly. The FF365 is gun-applied directly into the gap. Select the UL listed system that covers the conduit diameter and assembly type on your project.

3. Blank Openings and Unused Penetrations

Construction often leaves blank or partially filled openings that need to be closed before inspection. The FF365 can be applied directly to blank openings in walls or ceilings. For larger openings, use the FF365 in combination with the FF260 Fire Protection Block as backing material.

4. Hard-to-Reach and Irregular Penetrations

The sag-resistant formulation makes the FF365 reliable for overhead or angled applications. The gun-grade format allows precise placement in confined or awkward locations, including above ceiling tiles and inside wall cavities.

5. Small Membrane Penetrations

The FF365 is specifically rated for small membrane penetrations. This covers the typical penetration types found in multi-family residential, healthcare, data center, and other commercial construction where IBC fire-rated assembly requirements apply.

Common Sectors Where the FF365 Is Specified

  • Multi-family residential: IBC through-penetration requirements in rated floor/ceiling and wall assemblies
  • Healthcare and assisted living: strict fire compartmentalization in patient areas
  • Education: schools and university buildings with fire-rated corridor walls and floor/ceiling assemblies
  • Data centers: cable-dense environments with high through-penetration density
  • Hospitality and commercial: hotels, offices, and retail buildings with rated construction
A tube of TENMAT FF365 fire rated Fire Protection Sealant with a removable nozzle beside it on a white background.
Two tubes of TENMAT FF365 Fire Protection Sealant and Foam with separate nozzles on a white background.

Code Compliance and Test Standards

Through-penetration firestopping is a code-mandated requirement in the United States. Selecting a product tested and classified under the correct standards is a prerequisite for inspection sign-off.

International Building Code (IBC): Section 714

IBC Section 714 governs through-penetration firestop systems in fire-resistance-rated assemblies. It requires that penetrations be protected by a tested and listed firestop system installed per the manufacturer’s instructions. The FF365 is part of UL listed through-penetration systems that satisfy IBC 714 requirements.

UL 1479 and ASTM E814

The FF365 is tested and classified to UL 1479 (Standard for Fire Tests of Through-Penetration Firestops), which is equivalent to ASTM E814. Both are accepted under the IBC. The test evaluates:

  • F Rating: time in hours the assembly resists the passage of flame through the penetration
  • T Rating: time in hours before the non-fire-side temperature exceeds 325 degrees F above ambient, required for floor penetrations in most IBC applications

FF365 systems provide up to 2-hour F and T ratings, meeting the minimum IBC requirement for floor and wall penetrations in most fire-resistance-rated construction types.

NFPA 101 Life Safety Code

NFPA 101 includes firestopping requirements for egress-related assemblies and occupancy separations. Products installed in systems tested to UL 1479 / ASTM E814 satisfy NFPA 101 firestopping requirements.

UL Classified Systems

The FF365 fire rated sealant is a component in seven published UL listed through-penetration firestop systems. Each system number defines the specific combination of assembly type, penetrating item, annular space, and sealant. Match the system number to your project assembly when specifying or installing.

How to Apply the FF365 Fire Sealant

Installation follows the specific UL listed system that covers your project assembly. The general process is:

 

  1. Clean the component opening. Surfaces on which the Fire Protection Sealant FF365 is applied should be free of dirt, oil, wax and grease.
  2. Backfill material, consisting of mineral wool, must be used. For secure installation use pre-cut mineral wool batt insulation (4 pcf/ 64 kg/m3) firmly packed into annulus as a permanent form. It must be ensured that the minimum fill depth of the Fire Protection Sealant FF65 can be applied from both surfaces of the wall or top surface of the floor.
  3. Hold the cartridge cautiously, cut off the tip with a sharp knife, and screw on the nozzle. The nozzle can be shortened as needed.
  4. Insert the cartridge into the intended dispensing gun.
  5. Fire Protection Sealant FF365 must be introduced uniformly into the opening from back to front or bottom to top with a min. thickness of approx. 1/2” (13mm).
  6. Smoothing can be executed with a moistened smoothing trowel or brush.

 

Always install per the published UL system instructions. Deviating from the listed system voids the classification.

Product Details

The TENMAT FF365 Fire Protection Sealant is a red, one-component, gun-grade, intumescent firestop sealant for use in a variety of UL through-penetration firestopping systems.

TENMAT Fire Protection Sealants help properly fire rate small membrane penetrations in walls and ceilings and control the spread of flames and smoke in case of a fire for up to 2 hours.

The FF365 is suitable for irregular, hard-to-access, and small penetrations and can be used in combination with other TENMAT products such as the FF260 Fire Protection Blocks and the FF160 Fire Protection Plugs.

Recommended applications include: Blank openings, metal pipes, conduits, wires and mixed penetrations in solid floors and ceilings.

The FF365 Fire Protection Sealants fits into standard size 10 oz. caulking guns and can easily be applied within seconds.

The high expansion and insulating properties of the material ensures that both, flame spread and smoke, are stopped for 120 minutes. For a full list of our UL listed through-penetration firestopping systems, please visit the DOWNLOADS section.

Content 10.48 fl. oz

FF365 fire rated sealant vs other firestop products - feature comparison chart

Completing Your Firestopping System

The FF365 fire sealant works as a standalone solution in many applications, and as part of a combined system with other TENMAT passive fire protection products.

FF260 Fire Protection Block

A pre-formed intumescent block for larger penetration openings. Used as backing material for the FF365 sealant in cable tray and large opening applications.

FF360 Fire Protection Foam

A single-component intumescent firestop foam for irregular or larger through-penetrations where a gun-applied sealant is less practical.

FF160 Fire Protection Plug

A pre-formed intumescent plug for single cable and conduit penetrations in walls and floors. Often used alongside the FF365 in combination firestop assemblies.

View the full firestop foams, sealants and blocks range for the complete TENMAT through-penetration firestopping product family.

Quote Request | Enquiry

Need help? Call us now on 1-800-821-3436

Line drawing of a compass tool used for drawing circles, with part of a curved line beneath it—an ideal symbol for precision in Passive Fire Protection planning and design.

Architects & Specifiers

Line drawing of a house on a rolled architectural blueprint, emphasizing Passive Fire Protection in the construction plan.

Inspectors & Code Enforcement

Simple black outline of a house with a door and a slanted roof, symbolizing safety and Passive Fire Protection in home design.

Builders, Contractors & Developers

Black outline icon of a delivery truck facing right on a transparent background, ideal for businesses specializing in Passive Fire Protection services or deliveries.

Distributors